Project summary. This case describes a planning scheme for an island construction camp on Island X in the South Pacific. The camp is sized for 300 people on 12,136 sqm and is planned for a 12-month service period.

Accommodation, a dining hall and kitchen, toilets, showers, a medical center, offices, a recreation room, laundry and equipment rooms sit on one site. Power supply and distribution, water supply and drainage, network connectivity and fire safety are planned in the same package. Project stage: planning scheme.

Key Facts at a Glance

  • Island X in the South Pacific has a tropical climate with high humidity; salt spray corrosion and cyclone risks are listed as hazards.
  • The island construction camp is planned for 300 people on 12,136 sqm with a 12-month service period.
  • The restaurant and kitchen tent measures 42.5 m × 11 m × 2.8 m, and its public dining hall seats 108 people at the same time.
  • Six accommodation tents are planned: two Model 1 tents (38.2 m × 15.9 m × 4 m) and four Model 2 tents (36 m × 15.9 m × 4 m).
  • The clinic and office building is a two-story tent measuring 20 m × 15 m × 3 m.
  • Building foundations must be level to within 10 mm, with slopes at drainage points.
  • A total electrical load of 740 kW is reserved as a preliminary estimate.
Site layout dimension drawing of the 300-person island construction camp showing six accommodation tent blocks, central facilities and overall dimensions in millimetres
Flat dimension drawing of the camp site.

Project Data by Category

Project OverviewDining & Sanitation StructuresAccommodation & Support StructuresModel 1 vs Model 2Power Load by Area

Project Overview

Project Island X construction camp, South Pacific (planning scheme)
Location Island X, South Pacific
Climate conditions Tropical climate with high humidity; susceptible to salt spray corrosion and cyclone risks
Capacity 300 people
Planned area 12,136 sqm
Service period 12 months
Scope of planning Accommodation areas, dining hall, kitchen, restrooms, shower facilities, medical center, offices, recreation room, storage rooms, equipment rooms
Integrated systems Power supply and distribution, water supply and drainage, network connectivity, fire safety

Dining & Sanitation Structures

Building L × W × side/eave height Roof Walls Main frame
Restaurant & kitchen 42.5 × 11 × 2.8 m 850 g PVC tarpaulin + aluminum foil cotton insulation PEVA tarpaulin + aluminum foil cotton insulation 100 × 100 mm galvanized square steel tubing
Toilet 12.5 × 6 × 2.5 m 850 g PVC tarpaulin + aluminum foil cotton insulation PEVA tarpaulin + aluminum foil cotton insulation 80 × 80 × 2.0 mm galvanized square tubing
Shower room 25 × 9.5 × 3 m 850 g PVC fabric 650 g PVC sidewalls with windows 68 × 122 × 3.0 mm aluminum profile

Accommodation & Support Structures

Building L × W × side/eave height Roof Walls Main frame
Accommodation Model 1 (2 units) 38.2 × 15.9 × 4 m 850 g PVC fabric + aluminum foil cotton insulation 650 g PVC fabric + aluminum foil cotton insulation 112 × 203 × 4.0 mm aluminum profile
Accommodation Model 2 (4 sets) 36 × 15.9 × 4 m 850 g PVC fabric 650 g PVC fabric with aluminum foil insulation 112 × 203 × 4.0 mm aluminum profile
Recreation room 16.6 × 14.6 × 3 m 850 g PVC tarpaulin + aluminum foil cotton insulation 650 g PVC tarpaulin + aluminum foil cotton insulation 150 × 108 × 3.0 mm aluminum profile
Clinic/office (two-story) 20 × 15 × 3 m 850 g PVC fabric + aluminum foil insulation Solid walls + double-glazed tempered glass curtain walls 120 × 300 × 5.0 mm aluminum profile
Laundry room 36 × 12.4 × 3 m 850 g PVC fabric 650 g PVC fabric 88 × 166 × 3.0 mm aluminum profile
Equipment/storage room 42 × 10 × 5 m 850 g PVC fabric + aluminum foil insulation 650 g PVC sidewalls + fabric windows + aluminum foil cotton insulation 88 × 166 × 3.0 mm aluminum profile

Model 1 vs Model 2

Item Model 1 Model 2
Quantity 2 units 4 sets
Dimensions (L × W × eave height) 38.2 × 15.9 × 4 m 36 × 15.9 × 4 m
Roof 850 g PVC fabric + aluminum foil cotton insulation 850 g PVC fabric
Sidewalls 650 g PVC fabric + aluminum foil cotton insulation 650 g PVC fabric with aluminum foil insulation
Main frame 112 × 203 × 4.0 mm aluminum profile 112 × 203 × 4.0 mm aluminum profile

Power Load by Area

Area Reserved load
Accommodation area 500 kW
Dining hall and kitchen 80 kW
Hospital office area 50 kW
Equipment room 40 kW
Laundry room 30 kW
Outdoor camp area 20 kW
Shower room 10 kW
Recreation room 10 kW
Total reserved 740 kW

Project Background and Site Conditions

Island X lies in the South Pacific and has a tropical climate with high humidity. The project names two hazards: salt spray corrosion and cyclone risks. The brief is an island construction camp for 300 people that stays in service for 12 months.

The scope covers accommodation areas, a dining hall, kitchen, restrooms, shower facilities, a medical center, offices, a recreation room, storage rooms and equipment rooms. The stated goal is a camp that is safe, reliable, fully functional and adapted to the tropical island environment. CWTC's solutions page describes its integrated approach to tents, power, climate control, sanitation and furnishings.

Camp walkthrough. The sections below follow a visit through the camp: 01 entrance and master plan, 02 kitchen and dining, 03 toilets and showers, 04 accommodation, 05 clinic and support buildings, 06 foundation and utilities. Each colored square matches a zone on the master plan.

01 Master Plan and Entrance of the Island Construction Camp

The master plan places ten functional zones on one fenced site. Select a zone on the plan to jump to its section.

 Restaurant and kitchen 42.5 × 11 × 2.8 m
 Toilets 12.5 × 6 × 2.5 m
 Shower room 25 × 9.5 × 3 m
 Accommodation area Model 1: 38.2 × 15.9 × 4 m, 2 units
Model 2: 36 × 15.9 × 4 m, 4 sets
 Recreation room 16.6 × 14.6 × 3 m
 Hospital, office and meeting room 20 × 15 × 3 m, two-story
 Outdoor activity area Dimensions not stated
 Electric, water supply and other equipment room Equipment/storage room: 42 × 10 × 5 m
 Laundry room 36 × 12.4 × 3 m
 Parking lot Dimensions not stated
Master plan with ten color-coded functional zones.

 Entrances, Fence and Lighting

Camp lane map with the main entrance/exit, backdoor, 2.5 m perimeter fence and solar streetlights installed on the fence posts
Lane map: main entrance and exit, backdoor, 2.5 m recommended fence height, solar streetlights.

The lane map marks a Main Camp Entrance/Exit and a Backdoor. The perimeter fence has a recommended height of 2.5 m, and solar streetlights are installed on the perimeter fence posts.

Feature Perimeter fence at a recommended 2.5 m, with solar streetlights on the fence posts.
Advantage The lights share the fence posts instead of needing separate lighting poles.
Benefit The camp perimeter is fenced and lit by solar streetlights.

02 Camp Kitchen and Dining Hall Layout

The camp's receiving, cold storage, kitchen and dining hall sit in one tent, and its public dining hall seats 108 people at once. The restaurant and kitchen tent measures 42.5 m × 11 m × 2.8 m. Its roof is 850 g PVC tarpaulin with aluminum foil cotton insulation, and its walls are PEVA tarpaulin with aluminum foil cotton insulation. The main frame is 100 × 100 mm galvanized square steel tubing.

3D model of the 42.5 m restaurant and kitchen tent with a row of gabled roof sections
3D model of the restaurant and kitchen tent.
Color-coded floor plan of the camp restaurant and kitchen: pickup lane, freezer and refrigerated warehouses, receiving area, kitchen, utility room, public dining hall, private room and barrier-free access
Restaurant and kitchen floor plan with barrier-free access.

The restaurant floor plan labels the pickup lane, freezer warehouse, refrigerated warehouse, storage area, receiving/inspection area, rough processing area, kitchen area, utility room, public dining hall and private room, and marks barrier-free access.

Kitchen process flow from unloading to the dining hall. Hover or select a step to see what it holds.

 
 01
Unloading Area
 02
Receiving / Inspection Area
 03
Freezer and refrigerated warehouses
 04
Rough Processing Area
 05
Kitchen area / hot processing
 06
Pass-through window
 07
Public Dining Hall, 108 people at the same time
01 Deliveries reach the unloading area first.
02 The receiving/inspection area has one equipment cabinet, one inspection table and three trolleys.
03 A walk-in freezer, a walk-in cold store and a storage room with two 1.2 m freezers and four 1.8 m refrigerated display cabinets.
04 A meat and egg processing/washing station, a seafood preparation/cleaning station, and a fruit and vegetable preparation table and washing station.
05 Steamer, oven, soup pot, wok, gas stove, exhaust system, dishwasher and disinfection cabinet, among other items.
06 A food transfer window, a food pass-through window and a cold dish preparation room connect the work areas.
07 The public dining hall seats 108 people at the same time, with dining tables, a bar table, a food pickup and condiment station, a tableware sterilizer and a cold beverage cabinet.

 Receiving and Cold Storage

Deliveries reach an unloading area and a receiving/inspection area with one equipment cabinet, one inspection table and three trolleys. The same section holds a walk-in freezer, a walk-in cold store and a storage room with two 1.2 m freezers and four 1.8 m refrigerated display cabinets.

Receiving and cold storage layout with the unloading area, receiving/inspection area, freezer and refrigerated warehouses, plus reference photos of 1.2 m freezers and 1.8 m refrigerated display cabinets
Unloading, receiving and inspection, cold storage.

 Kitchen Processing

Kitchen processing layout showing rough processing, hot processing, pass-through windows and utility room, with reference photos of dishwashing and water-heating equipment
Rough processing, hot processing and utility room.

The rough processing area includes a meat and egg processing/washing station, a seafood preparation/cleaning station, and a fruit and vegetable preparation table and washing station. The hot processing and cleaning area covers steamer, oven, soup pot, wok, gas stove, exhaust system, dishwasher and disinfection cabinet, among other items.

A food transfer window, a food pass-through window and a cold dish preparation room connect the work areas. The utility room holds an air shower, a 700 L water heater, a sedimentation tank and an oil-water separator.

 Public Dining Hall and Private Room

The public dining hall is planned for 108 people dining at the same time, with dining tables, a bar table, a food pickup and condiment station, a tableware sterilizer and a cold beverage cabinet. A private room has a dining table, sofa, coffee table and sideboard.

Feature Separate zones for pickup lane, receiving/inspection, freezer and refrigerated warehouses, rough processing, kitchen, utility room, public dining hall and private room.
Advantage Receiving, cold storage, cooking and dining sit in one connected tent, with pass-through windows between processing and serving areas.
Benefit The camp serves 300 residents from one kitchen building, and 108 people can be seated at once.
Public dining hall plan seating 108 people with a private room, plus reference photos of dining tables, tableware sterilizer and cold beverage cabinets
Public dining hall for 108 people and private room.

03  Toilet and Shower Facilities

The camp has a 12.5 m × 6 m toilet tent and a 25 m × 9.5 m shower room, and both include accessible provisions.

 Toilet Tent

3D model of the 12.5 m × 6 m toilet tent with a gabled roof and window openings in the white wall
Toilet tent 3D model.

The toilet tent measures 12.5 m × 6 m × 2.5 m. It has an 850 g PVC tarpaulin roof, PEVA tarpaulin walls, aluminum foil cotton insulation and an 80 × 80 × 2.0 mm galvanized square tubing frame.

TOILET DRAWINGS
Floor planCirculation planZoning plan
Floor plan

The toilet floor plan separates the urinal area, men's toilets, storage rooms, washbasin area, women's toilets, and accessible toilets with a mother-and-baby area.

Circulation plan

The circulation plan uses colored arrows to mark movement routes through the urinal area, men's toilets, washbasin area, women's toilets and accessible toilets.

Zoning plan

The zoning plan pairs each zone with a photo: urinal partitions, storage room, washbasin, accessible toilet and toilet cubicles.

Toilet tent floor plan with urinal area, men's toilets, women's toilets, accessible toilets and mother-and-baby area, washbasin area and storage rooms
Toilet floor plan.
Toilet tent circulation plan with colored arrows showing movement routes through the urinal, men's, women's, accessible and washbasin zones
Toilet circulation plan.
Toilet tent zoning plan with fixture photos of urinal partitions, storage room, washbasin, accessible toilet and toilet cubicles
Toilet zoning plan with fixture photos.

 Shower Room

White PVC fabric tent with outdoor air conditioner units, shown as a reference for the 25 m × 9.5 m shower room tent
Shower room tent (illustrative image).

The shower room measures 25 m × 9.5 m × 3 m. The roof is 850 g PVC fabric, the walls are 650 g PVC sidewalls with windows, and the main material is 68 mm × 122 mm × 3.0 mm aluminum profile.

SHOWER ROOM DRAWINGS
Floor planCirculation planZoning plan
Floor plan

The shower floor plan includes a washing area, men's and women's changing rooms and shower rooms, toilets, an accessible shower and an equipment room for hot water systems and water storage and distribution equipment.

Circulation plan

The circulation plan marks movement through the washing, changing and shower areas with arrows.

Zoning plan

The zoning plan pairs the washbasin, locker room lockers, toilet, shower, accessible shower and locker room benches with photos.

Feature Accessible toilets, a mother-and-baby area and an accessible shower are drawn into the toilet and shower plans.
Advantage Each facility has its own circulation plan and zoning plan, so the user routes are defined before construction.
Benefit Residents who need accessible facilities have dedicated space inside the camp.
Shower room floor plan with washing area, men's and women's changing rooms, shower rooms, accessible shower and equipment room
Shower room floor plan.
Shower room circulation plan with arrows showing movement through the washing, changing and shower areas
Shower room circulation plan.
Shower room zoning plan with fixture photos of washbasin, lockers, toilet, shower, accessible shower and locker room bench
Shower room zoning plan with fixture photos.

04 Accommodation Tents for 300 People

Two Model 1 tents (38.2 m × 15.9 m × 4 m) and four Model 2 tents (36 m × 15.9 m × 4 m) provide the accommodation. Both models use a 112 mm × 203 mm × 4.0 mm aluminum profile frame.

ACCOMMODATION TENT: RENDERING AND PLANS
RenderingZoning planDimension drawingsFurniture board
Rendering of an accommodation tent with an arched white roof and arched windows along the side wall
Accommodation tent rendering.
Accommodation tent zoning plan showing 3-person, 2-person and 1-person rooms, washrooms and corridors, with a capacity of 50 people per tent
Accommodation zoning plan with room types and corridors.
Dimension drawings and specifications of the Model 1 (38.2 m × 15.9 m × 4 m) and Model 2 (36 m × 15.9 m × 4 m) accommodation tents with room layouts
Dimension drawings of Model 1 and Model 2.
Furniture reference board for the camp rooms: knock-down bunk bed, single bed, desk, wardrobe and four-person table and chair set
Furniture reference board; all furniture is knock-down type.
Rendering

Roofs are 850 g PVC fabric and sidewalls are 650 g PVC fabric; Model 1 adds aluminum foil cotton insulation to roof and sidewalls, and Model 2 lists aluminum foil insulation in the walls. CWTC has supplied aluminum frame tents on other projects, such as the Rwanda Police aluminum frame tent and inflatable tent project.

Zoning plan

Each tent layout offers 3-person, 2-person and 1-person rooms, corridors and a washroom with a stainless steel sink, a mop sink and a keypad-lock cabinet. The zoning plan lists a capacity of 50 people, counting each upper or lower bunk as one person.

Dimension drawings

Dimension drawings are given for Model 1 (38.2 m × 15.9 m × 4 m, 2 units) and Model 2 (36 m × 15.9 m × 4 m, 4 sets).

Furniture board

The furniture reference board shows a bunk bed, single bed, desk, wardrobe and a 4-person table and chair set. All furniture is knock-down (assembly-required) type.

Feature Six aluminum-frame tents with 3-person, 2-person and 1-person rooms and knock-down furniture.
Advantage Mixed room sizes sit in one tent layout, and flat-pack furniture is assembled on site.
Benefit Six tents at 50 people each add up to the 300-person capacity.

05    Clinic, Recreation and Support Buildings

Four supporting buildings complete the camp: a two-story clinic and office, a recreation room, a laundry room and an equipment/storage room.

 Clinic and Office Building

The clinic and office is a two-story tent of 20 m × 15 m × 3 m, built on a 120 mm × 300 mm × 5.0 mm aluminum frame with solid walls and double-glazed tempered glass curtain walls.

The ground floor holds the service desk, waiting area, consultation rooms, observation room, debridement and dressing room, resuscitation room, patient room, duty room, storage room, toilets and a payment and medication collection counter. The second floor holds offices, a meeting room, a resource room and a tea bar. For field medical units, see CWTC's mobile hospital range.

Two-story tent building with glass curtain walls and a balcony, a reference for the 20 m × 15 m clinic and office building
Clinic and office building (illustrative image).
CLINIC AND OFFICE DRAWINGS
Zoned floor planDimensioned plan
Zoned floor plan of the clinic and office: ground-floor consultation, observation, resuscitation and patient rooms; second-floor offices and meeting room
Zoned floor plan: ground-floor medical rooms, second-floor offices.
Dimensioned plan of the clinic and office with the ground-floor medical rooms and second-floor offices labeled
Dimensioned plan: ground-floor medical room and second-floor office.
Zoned floor plan

The ground-floor and second-floor plans carry a legend covering stairwell, offices, meeting room, resource room, corridor, tea bar and a double-height area.

Dimensioned plan

The dimensioned plan labels the ground-floor medical room and the second-floor office with room names and dimensions.

Feature Two-story tent with medical rooms on the ground floor and offices and meeting rooms above.
Advantage Medical and administrative functions share one building instead of two.
Benefit The camp has on-site medical rooms for its 300 residents.

 Recreation Room

The recreation room is 16.6 m × 14.6 m × 3 m with a 150 mm × 108 mm × 3.0 mm aluminum frame. It includes a prayer room, a card and board game room and a TV room, separated by solid partition walls for sound insulation.

White tent with glass walls among palm trees on a sandy bay shore, a reference for the 16.6 m × 14.6 m recreation room
Recreation room tent (illustrative image).

 Laundry Room

Laundry room reference images: glass-walled tent frame and a row of industrial washing machines
Laundry room (illustrative images).

The laundry room measures 36 m × 12.4 m × 3 m with an 88 × 166 × 3.0 mm aluminum profile frame, an 850 g PVC fabric roof and 650 g PVC fabric walls.

 Equipment and Storage Room

The equipment/storage room measures 42 m × 10 m × 5 m with an 88 × 166 × 3.0 mm aluminum profile frame, an aluminum foil insulated roof, and 650 g PVC sidewalls with fabric windows and aluminum foil cotton insulation. At 5 m, it has the highest eave height among the structures listed for the camp.

Large white gabled tent with glass sidewalls, a reference for the 42 m × 10 m equipment and storage room
Equipment and storage room tent (illustrative image).

06  Foundation, Power and Drainage

The foundation is leveled concrete with a 10 mm tolerance, power is reserved at 740 kW, and drainage runs to the municipal main.

SITE UTILITY DRAWINGS
Ground elevationElectricity planDrainage points
Ground elevation diagram marking 0.2 m compacted concrete leveling and 0.4 m floor concrete height, with a foundation tolerance of 10 mm
Ground elevation diagram.
Camp electricity plan with the reserved 740 kW load listed by zone: accommodation, dining hall and kitchen, equipment, hospital office, laundry, shower and recreation rooms
Electricity plan with 740 kW reserved load.
Drainage point layout of the camp with sewer wells marked as blue dots; the 3 m deep wells connect to the municipal main drainage pipeline
Drainage point layout map.
Ground elevation

Ground preparation calls for concrete floor leveling and compaction 0.2 m thick, with a floor concrete height of 0.4 m. All building foundations must be level to within 10 mm, and slopes must be provided at drainage points.

Electricity plan

A total electrical load of 740 kW is reserved. This figure is a preliminary estimate to be refined against specific requirements. Accommodation is allocated 2 kW per unit for lighting and power outlets. Outdoor camp facilities include mosquito-control lamps, decorative lighting and a public address system.

Drainage points

The sewer well is 3 m deep, and underground drainage pipes lead to the municipal main drainage pipeline.

Feature Leveled foundations (tolerance 10 mm), sloped drainage points, 3 m sewer wells and a 740 kW reserved load.
Advantage Ground, power and drainage are specified together with the tents, so the site is prepared as one system.
Benefit The camp has a defined power reserve of 740 kW and a defined drainage route to the municipal main.

Project Highlights

  1. Every listed function of the island construction camp, from accommodation to equipment rooms, is placed on one site plan.
  2. The kitchen runs from unloading and inspection through cold storage and processing to a 108-seat dining hall.
  3. Accessible toilets, a mother-and-baby area, an accessible shower and barrier-free restaurant access are drawn into the plans.
  4. A two-story clinic and office building puts medical rooms and offices in one structure.
  5. Foundation tolerance, drainage slopes, sewer wells and a 740 kW reserved load are specified with the tents.

Frequently Asked Questions

Hover over a question to open its answer; move away and it closes. On touch screens, tap a question to open or close it.

What is the South Pacific island construction camp project? 

It is a planning scheme for a construction camp on Island X in the South Pacific. The camp is planned for 300 people on 12,136 sqm and a 12-month service period, with accommodation, dining, sanitation, medical, office, recreation, laundry and equipment facilities.

How many people can the camp house? 

The camp is planned for 300 people. Six accommodation tents are planned, and each accommodation zoning plan lists a capacity of 50 people, counting each upper or lower bunk as one person.

Does the camp include medical facilities? 

Yes. A two-story clinic and office tent is planned. The ground floor has consultation, observation, resuscitation and patient rooms, and the second floor has offices and a meeting room.

What are the tents made of? 

Roofs are 850 g PVC fabric or tarpaulin and walls are 650 g PVC fabric, PEVA tarpaulin or solid walls with glass, depending on the building. Frames are galvanized square steel tubing for the restaurant and toilet, and aluminum profile for the other buildings.

How are power and drainage planned? 

A total electrical load of 740 kW is reserved as a preliminary estimate. Drainage uses 3 m deep sewer wells with underground pipes leading to the municipal main drainage pipeline.

Has this camp been built? 